APC Back-UPS Pro Specifications Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
Back-UPS BR900G-RS Installation and Operation
7
Function Quick-Reference
Function Button
Timing
(seconds)
UPS
Status
Description
Power
POWER ON
0.2 Off Press the POWER ON/OFF button to turn on the Back-UPS and
operate on AC power.
If AC input power is not available the Back-UPS will operate on
battery power.
POWER OFF
2OnPress the POWER ON/OFF button to turn off the Back-UPS.
The Back-UPS will continue to provide surge protection to the
Surge Protection outlets.
Display
Status Inquiry 0.2 On Verify the status or condition of the Back-UPS. The LCD will
illuminate for 60 seconds.
Power-Saving
mode:
Continuous
Illumination
2 On The LCD will illuminate and the Back-UPS will beep to confirm
Continuous Illumination mode is activated.
The LCD will extinguish and the Back-UPS will beep to confirm
that
Power-Saving mode is activated. While in Power-Saving mode,
the LCD will illuminate if a button is pressed, then extinguish after
60 seconds of no activity.
Mute
Event Specific 0.2 On Disable any audible alarms caused by an event.
General Status
Enable/Disable
2 On Enable or disable the audible alarms. The Mute icon will illuminate
and the Back-UPS will beep one time. The Mute feature will not
activate unless the Back-UPS is operating on battery power.
Sensitivity 6 Off The Load Capacity icon will flash to indicate the Back-UPS is in
Program mode. Use the
POWER ON/OFF button to scroll through
and select Low, Medium, and High sensitivity levels. The Back-
UPS will beep to confirm the selection. Refer to “Power Saving
Feature” on page 4 for details.
MASTER/
CONTROLLED outlet
Enable/Disable
2 On The leaf icon will extinguish to indicate the
MASTER outlet feature
is disabled or illuminate to indicate the
MASTER outlet feature is
enabled. The Back-UPS will beep once.
Master/Enable
threshold calibration
6 On While calibrating the threshold setting, the device connected to the
MASTER outlet should be turned off or placed in Standby or Sleep
mode. Once the threshold setting has been selected the Power-
Saving icon will flash 3 times and beep 3 times.
Self-Test (manual) 6 On The Back-UPS will run a test of the internal battery.
Note: This will happen automatically when the Back-UPS is turned
on.
Event Reset 0.2 On When the Event screen is visible, press and hold
DISPLAY, then
press the
POWER button to clear the AC failure event counter.
Fault Reset 2 Fault After a fault has been identified, press the
POWER ON/OFF button to
remove the visual indication and return to standby status.
Page view 6
1 2 3 4 5 6 7 8 9 10

Comments to this Manuals

No comments