Capacity (MB/GB): Use drives with the same capacity. RAID arrays use a “least-
common-denominator” approach meaning the maximum
capacity of each drive in the array is the maximum capacity
of the smallest drive.
Profile: The drive trays and bays of the system are designed for 3.5-
inch wide x 1-inch high hard drives.
Drive type: The 24 BAY subsystem can use either SATA-II or SATA-I
interface hard drives.
2.7.3 Drive Installation
Step 1. Place the SATA hard drive into the drive tray. (See Figure 2-6) Make
sure the hard drive is oriented in such a way that the drive’s SATA
connector is facing the back of the drive tray.
Figure 2-6: Installing a SATA Hard Drive
Step 2. Adjust the drives location until the mounting holes in the drive canister
are aligned with those on the hard drive. Secure the drive with four (4)
supplied 6/32 flathead screws. (See Figure 2-6)
WARNING!
Only use screws supplied with the drive canisters. Longer screws may damage the
hard drives.
2.8. Drive Tray Installation
Before drive tray installation, you need to access the drive bays on the
left- and right-side columns:
Drive Tray Installation
2-11