TV and radio circuits be confi gured to use proper-sized
and installed UPS. Please follow instructions in UTS6H
manual for UPS’s sizing and installation.
Heat Rejection System
6.
Heat rejection kit (sold separately) is required for
backup mode operation during times when no space
heating or water heating is required.
A water cooled heat rejection system is available •
for installations where there is uninterrupted supply
of water during power outage (city water). Kit ties
into main water supply line and discharges water to
appropriate drain. Drain must be suitable for 0.35
GPM at 180° F. Kit contains ball valve, pressure
reducer, electronic ball valve, and fl ow reducer.
Installer must supply piping to tie into main water
line, and deliver water to appropriate drain.
Installations without uninterrupted supply of water •
during power outage (most houses with well pumps)
air cooled heat rejection system is available.
Contains vertically arranged side discharge fan-coil
unit installed outside, and is connected to HI Module
through closed coolant loop. Dimensions of unit are
24" Length, 15" Width, and 36" Height.
Air cooled heat rejection system installer must •
supply secure mounting pad or foundation, power
wiring, low voltage wiring (18 AWG minimum),
and closed Propylene Glycol coolant loop from
HI Module to unit (3/4" piping, circulator, air
separator, pressure relief valve, expansion tank,
fl ow check, and purge valve). See FWHRJ Air
cooled heat rejection system Installation, Operation,
Maintenance manual for specifi c installation
instructions.