Summary of Contents

Page 1 - User’s Manual

990-1021, Revision 1 5/00User’s ManualEnglishAPC Smart-UPS1400 VA 3U Rack and StackUninterruptible Power Supply120 Vac

Page 2 - 990-1021, Revision 1 5/00

6Place The UPS Where It Will Be UsedSelect a location with adequate air flow that is free from excessive dust. Ensurethat the air vents on the front

Page 3 - Table of Contents

7To Mount the UPS in a RackThe UPS comes with standard 19-inch (46.5 cm) rack mount brackets (in the literature kit) andmounting rails and cleats. Th

Page 4

87. Expand the rail so that it spans from the front rack postto the back rack post.8. Use three screws and washers to attach the rail to theback rac

Page 5 - Handling Safety

9Load the UPS into the RackDue to the weight of the UPS, two people are required to install it in the rack.1. Use the handles  on the side of theUPS

Page 6 - Battery Safety

10the cutout section on the right. Align the tabson the side of the bezel with the slots on thefront of the UPS and firmly snap it into place.To conn

Page 7 - Limited Warranty

11Turn on the UPSMake sure the battery is connected before turning on the UPS!• Press the UPS’s on |TEST button, located on the front panel, to powe

Page 9 - How To Install the Smart-UPS

13CHAPTER 4: OPERATING THE SMART-UPSIndicators and Controls on the Smart-UPSThe Smart-UPS has the power control and operating indicators located on t

Page 10 - B atte ry

14On BatteryDuring on-battery operation, the on-battery LED illuminates and the UPS sounds an audible alarmconsisting of four beeps every 30 seconds.

Page 11

15Voltage TrimThe voltage trim LED comes on to indicate that the UPS is compensating for a high utilityvoltage.Voltage BoostThe voltage boost LED come

Page 12

990-1021, Revision 1 5/00Entire contents copyright © 2000 by American Power Conversion Corporation. All rightsreserved. Reproduction in whole or in

Page 13

16Smart-UPS Rear PanelMADE IN USA (WEST KINGSTON, RI)SU1400RMX L3UXX0123456789®Computer Interface PortPower management software and interface kits can

Page 14

17Battery Pack ConnectorUse the battery pack connector to connect optional external battery pack(s). The SU1400RMXLsupports up to ten (10) external b

Page 15 - Turn on the UPS

18How To Determine On-Battery Run TimeUPS battery life differs based on usage and environment. It is recommended that thebattery/batteries be changed

Page 16

19User Configuration ItemsNote: Setting these items requires optional software or hardware.Function FactoryDefaultUser SelectableChoicesDescriptionAut

Page 18

21CHAPTER 5: MAINTENANCE AND TROUBLESHOOTINGStorageStorage ConditionsStore the UPS covered and flat (rack mount orientation) in a cool, dry location,

Page 19

221. Face the front of the UPS and, using both hands, insert eachindex finger behind the lip of the curved section of the frontbezel and pull towards

Page 20 - Smart-UPS Rear Panel

23TroubleshootingUse the chart below to solve minor UPS installation problems. Contact APC Technical SupportStaff for assistance with complex UPS pro

Page 21 - On-Battery Operation

24All indicators are lit and UPS emits a constant beeping• Internal UPS fault.Do not attempt to use the UPS. Turn the UPS off and have itserviced im

Page 22

25APPENDIX A: SPECIFICATIONS1400 VA (SU1400RMXL3U)Normal input voltage 120 Vac single phase, 50 or 60 Hz (auto-selectable)Input plug NEMA 5-15P 6 ft

Page 23 - User Configuration Items

990-1021, Revision 1 5/00Table of ContentsChapter 1: Safety Information...1Conventions Us

Page 24

26Storage relative humidity 0 to 95%, non-condensingStorage elevation 0 to +15,000 m (0 to +50,000 ft)Electromagnetic immunity IEC 801-2 level IV, 801

Page 25 - Replacing the Battery

27APPENDIX B: TRANSPORTING YOUR SMART-UPSFollow these guidelines if you need to ship the UPS to another location. These guidelines applywhether you

Page 26

990-1021, Revision 1 5/00Service ...24Appendix A: Spec

Page 27 - Troubleshooting

1CHAPTER 1: SAFETY INFORMATIONThis Safety Guide contains important instructions that should be followed during the installationand maintenance of the

Page 28

2Electrical Safety• To reduce the risk of fire, connect only to a circuit provided with a 20 Amp maximum branchcircuit overcurrent protection in acco

Page 29 - APPENDIX A: SPECIFICATIONS

3CHAPTER 2: BASICSAbout Your UPSThis APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sagsand surges from reaching

Page 30 - LISTED 42C2

4How To Contact APCInternethttp://www.apcc.com/contactNorth AmericaPhone 1.800.800.4272Fax 1.401.788.2743Latin AmericaArgentina 0800.9.APCC (0800.9.27

Page 31

5CHAPTER 3: INSTALLING YOUR SMART-UPSUnpackingAPC has taken care to design robust packaging for your product. However, accidents and damagemay occur