APC AP9215 Specifications Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
UPS card for network administrators to control and monitor power through a dry
contact interface in rack, computer room, and datacentre environments.
Dry contact management for telecom and alarm-type systems
The Relay I/O Card allows you to control and monitor power through a simple
dry-contact interface, a communication format common in PBXs, telecom, and
alarm management systems. The Card easily installs in your APC Smart-UPS,
Matrix-UPS, or Symmetra Power Array system and fully integrates with your
telecom and dry contact equipment.
Features include:
Allows you to remotely monitor the UPS battery and operation when the power
goes out. This monitoring is critical to maintaining remote site availability.
Gives you the ability to remotely start up or stop equipment via four input and
output relay contacts.
Can remotely reboot locked-up or unstable devices, saving you time and the
added expense of a field service call.
Relay I/O Card
Environmental Monitoring Card
Part Number AP9612TH (Temperature and Humidity)
UPS card for network administrators to monitor environmental conditions in rack,
computer room, and datacentre environments.
Environmental monitoring
The Environmental Monitoring Card will remotely monitor temperature, humidity
and other environmental conditions via PowerChute plus, the Out-of-Band
Management Card, the Web/SNMP Management Card, SNMP Agents or
PowerView.
Features include:
External probes for temperature and humidity continuously monitor the envi-
ronment of your valuable equipment.
A remote probe that allows you to monitor the environment up to 12’ (366cm) from
the UPS or from the Environmental Monitoring Card.
Compatibility with closed/open loop sensors.
Contacts are accompanied by a 12V DC power source, allowing more flexibility
in sensor options.
APC PowerChute plus software provides a graphical user interface as
well as administrator notification of environmental problems. The FlexEvents
feature in PowerChute plus allows Environmental Monitoring Card information
to trigger a number of user-defined events, including paging, event logging
and safe system shutdown.
User-selectable thresholds that allow you to decide when you need to be
notified of potential environmental problems to prevent damage to system
components.
Availability to work in conjunction with APC SNMP Agents, the Web/SNMP
Management Card with PowerView and the Out-of-Band Management Card
for network, as well as modem-based, communication of system environ-
mental conditions.
Part Number AP9610