Appendix
D-3
Initialization
Event ID
0x1c01
Type
RAID
Severity
INFO
Parameters
VOL ID
Message
VOLx deleted
Description
volx was deleted.
Advice
None
Event ID
0x204c
Type
RAID
Severity
INFO
Parameters
DG ID
Message
Write-zero init on DGx started
Description
Disk group zeroing task on dgx was started.
Advice
None
Event ID
0x204d
Type
RAID
Severity
INFO
Parameters
DG ID, LD ID
Message
Logical disk init on DGxLDy started
Description
Logical disk initialization task on dgxldy was started.
Advice
None
Event ID
0x204e
Type
RAID
Severity
NOTICE
Parameters
DG ID
Message
Write-zero init on DGx completed
Description
Disk group zeroing task on dgx was completed.
Advice
None
Event ID
0x204f
Type
RAID
Severity
NOTICE
Parameters
DG ID, LD ID
Message
Logical disk init on DGxLDy completed
Description
Logical disk initialization task on dgx was completed.
Advice
None
Event ID
0x2050
Type
RAID
Severity
WARNING
Parameters
DG ID
Message
Write-zero init on DGx aborted
Description
Disk group zeroing task on dgx was aborted.
Advice
Check if any disks in the disk group failed, and then re-create the disk group.