APC RAID Subsystem SCSI-SATA II Technical Information Page 250

  • Download
  • Add to my manuals
  • Print
  • Page
    / 259
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 249
Appendix
D-53
Firmware update
Event ID
0x2414
Type
SYSTEM
Severity
NOTICE
Parameters
Message
Auto-write-through de-activated
Description
The pre-defined triggering events for auto-write-through have gone, and the controller restored the
original cache setting.
Advice
None
Event ID
0x2418
Type
SYSTEM
Severity
NOTICE
Parameters
Message
Auto-shutdown activated
Description
The pre-defined triggering events for auto-shutdown occurred, and the controller was going to
shutdown itself.
Advice
Check the event logs, and remove the causes of events that trigger auto-shutdown. Restart the
controller. Disable auto-shutdown first before starting investigating the causes.
Event ID
0x2419
Type
SYSTEM
Severity
FATAL
Parameters
Message
NVRAM event log checksum error
Description
The checksum stored on NVRAM for event log cannot match the contents on NVRAM. This could
happen if the controller was not properly shutdown. Because the event log on NVRAM might be
corrupt and cannot be trusted, all event logs will be erased automatically.
Advice
If this event continuously happens, contact local sales or support office.
Event ID
0x2407
Type
SYSTEM
Severity
INFO
Parameters
Controller ID
Message
System firmware in controller x updated
Description
System firmware in controller x was updated successfully.
Advice
Restart the controller so that the new firmware can be effective.
Event ID
0x2408
Type
SYSTEM
Severity
INFO
Parameters
Controller ID
Message
Controller x failed to update system firmware
Description
The controller x cannot update the system firmware.
Advice
Check the firmware file is not corrupt and has the correct version.
Page view 249
1 2 ... 245 246 247 248 249 250 251 252 253 254 255 ... 258 259

Comments to this Manuals

No comments