Appendix
D-40
D.5 Controller hardware
Memory
Flash chip
Event ID
0x3031
Type
HOST
Severity
INFO
Parameters
Initiator Name,
Target ID
Message
Initiator x log off target y
Description
The controller detected Initiator x log off target y.
Advice
If initiator quitted unexpectedly, or it happens continuously during host access, check the host con-
nectivity, or contact local sales or support office.
Event ID
0x241e
Type
CONTROLLER
Severity
WARNING
Parameters
Controller ID, Sin-
gle-bit error
address
Message
Memory ECC single-bit error in controller x: y
Description
The controller x has detected and corrected single-bit error in the memory module.
Advice
Check if the memory module is installed properly, and make sure the memory module is in the
compatibility list. Replace the memory module, and if the error continuously happens, contact local
sales or support office.
Event ID
0x2421
Type
CONTROLLER
Severity
ERROR
Parameters
Controller ID
Message
Primary system flash in controller x is corrupt
Description
The primary system flash chip on controller x is corrupt and cannot be used. But the secondary
flash still works.
Advice
Check if there are any hardware hazards that lead to abnormal flash corruption. Watch the sec-
ondary flash chip.
Event ID
0x2422
Type
CONTROLLER
Severity
ERROR
Parameters
Controller ID
Message
Secondary system flash in controller x is corrupt
Description
The secondary system flash chip on controller x is corrupt and cannot be used. But the primary
flash still works.
Advice
Check if there are any hardware hazards that lead to abnormal flash corruption. Watch the sec-
ondary flash chip.