APC RAID Subsystem SCSI-SATA II Technical Information Page 209

  • Download
  • Add to my manuals
  • Print
  • Page
    / 259
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 208
Appendix
D-12
Logical disk shrink
Disk group defragmentation
Event ID
0x200e
Type
TASK
Severity
NOTICE
Parameters
DG ID, LD ID
Message
DGxLDy shrinked
Description
DGxLDy shrinked
Advice
Make sure partitions or file systems on the logical disk have been shrunk before conducting the
logical disk capacity shrink. After finishing, hosts might need to rescan the LUN of the logical disk
to get the updated capacity.
Event ID
0x2010
Type
TASK
Severity
INFO
Parameters
DG ID
Message
Defragment on DGx started
Description
Disk group defragment on dgx was started manually.
Advice
None
Event ID
0x2033
Type
TASK
Severity
NOTICE
Parameters
DG ID
Message
Defragment on DGx started by schedule
Description
Scheduled disk group defragment on dgx was started.
Advice
None
Event ID
0x2047
Type
TASK
Severity
WARNING
Parameters
DG ID
Message
Defragment on DGx failed to start by schedule
Description
Scheduled disk group defragment on dgx failed to start.
Advice
Check if the disk group is busy or non-optimal when starting the task.
Event ID
0x2013
Type
TASK
Severity
NOTICE
Parameters
DG ID
Message
Defragment on DGx paused
Description
Disk group defragment on dgx was paused.
Advice
Check if there is failed member disk in the disk group during the task.
Event ID
0x2014
Type
TASK
Severity
NOTICE
Parameters
DG ID
Message
Defragment on DGx resumed
Description
Disk group defragment on dgx was resumed.
Advice
None
Page view 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 258 259