4.4 Replacing an APC Unit
If you remove a failed APC unit, you must replace it as quickly as possible (within five
minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.
If you do not have a replacement APC unit available for immediate installation, you must
power off the enclosure.
NOTE :
If the enclosure is still operational, the failed APC can be left installed to
maintain proper cooling until a replacement unit is available. The fans in
both APCs will continue to run at high speed until the APC unit is replaced.
To replace an APC unit:
1. Power off the failed APC unit and remove the power cable.
If
the enclosure is powered on, the fans in the other APC unit switch to high
speed to
compensate for the reduced airflow.
2. Push the release tab to the right and rotate the handle down (Figure
32).
Figure 32. Release Tab and Handle on APC Unit
Handle
Release T ab
3. Slide the APC unit out of the bay. Do not use the release tab as a handle to lift or carry
the APC unit.
4. Gently slide a new APC unit into the bay until the handle rotates up and the release tab
clicks into place.
5. Reconnect the power cable.
6. Turn on the APC unit.