Advanced View: Defining Thresholds
150 Using Your Appliance
c.When you have finished creating your Advanced Threshold, click OK to save the schedule and
return to the Thresholds task.
Select an Alert Severity value for this threshold. Available Alert Severities are, in order of
escalating severity: Information, Warning, Error, Critical, or Failure. By default, the Alert
Severity generated by this threshold will be “Error.”
Specify the Alert Profile that will be used to determine what alert notification actions will be
taken in response to this threshold. By default, the Default Alert Profile is used for all thresholds.
However, if you have created additional Alert Profiles you can specify that a threshold use an
Alert Profile other than Default.
Select Cameras to Trigger in response to the alert. If desired, alert notifications generated in
response to this threshold can include image captures from any Camera Pod 120s connected to
your appliance. To include images from one or more connected Camera Pod 120s, check the
check boxes that correspond to the desired pods.
–Specify a User-specified URL and User-specified Description. You can use these fields to
include additional user-specific information with any alert notifications that are generated using
this threshold.
8. Click OK to save this threshold.
Rate of Decrease Threshold
A rate of decrease threshold is defined by specifying a maximum acceptable decrease in value for the
sensor and a period of time value. If the value reported by the sensor falls by more than the specified
maximum acceptable decrease in less than the specified period of time an alert condition is reported. To
define a rate of decrease threshold:
1. Start the Camera Pods, Sensor Pods, or Device Crawlers task by double-clicking on the appropriate
icon.
2. Click Sensors... to open the Sensor Configuration window.
3. Select from the Sensors selection list the sensor for which you will define a threshold. A list of
thresholds that have been previously defined for the selected sensor, if any, appears in the
Thresholds selection list.
4. Click Add... to open the Select Threshold window. Select Rate of Decrease Threshold and then
click OK to close the Select Threshold window.
5. Type in the Threshold Name field a name for this threshold.
6. Specify Basic threshold settings. From the Basic tab in the Thresholds pane:
a. Type in the Maximum Decrease field (or use the arrows in the field to specify) the highest
acceptable change value for the selected sensor. If the value reported by the sensor decreases by
more than the Maximum Decrease value in a period of time that is equal to or less than the
number of seconds specified in the Time Period field, an alert condition results.
b. Type in the Time Period field (or use the arrows in the field to specify) the number of seconds
that defines the unacceptable change period. If the value reported by the sensor decreases by
Note
The Alert Profile drop box will appear in the Advanced tab only if additional
Alert Profiles have been created. For more information see “Creating an Alert
Profile” on page 63.