Chapter 6:
[sPDUMasterConfigVM] Master Configuration OIDs
PowerNet MIB Reference Guide
46
OID Task
sPDUMasterConfigVMTableSize
The number of MasterSwitch VM units.
{sPDUMasterConfigVMTable}
{sPDUMasterConfigVMEntry}
sPDUMasterConfigVMIndex
sPDUMasterConfigVMName
sPDUMasterConfigVMColdstartDelay
sPDUMasterConfigVMAudioAlarmActivated
sPDUMasterConfigVMHighLoadWarningThreshold
sPDUMasterConfigVMLowLoadWarningThreshold
sPDUMasterConfigVMOverloadRestriction
View and configure a specified MasterSwitch VM unit.
The index to the MasterSwitch VM unit
s entry (read-only).
Define a name (up to 23 characters) for the MasterSwitch
VM unit.
Define the delay that will occur from the time that power is
applied to the MasterSwitch VM unit until it supplies power
to its outlets:
- -1: Never start providing output power automatically.
- 0: Begin providing output power immediately.
- 15: 15-second delay
- 20: 20-second delay
- 30: 30-second delay
- 45: 45-second delay
- 60: 1-minute delay
- 120: 2-minute delay
- 300: 5-minute delay
Define the following by using a SET:
- audioAlarmActiveNever (1): Disable the audio alarm.
- audioAlarmActiveOnOverload (2): Cause the audio
alarm to sound when an overload condition occurs.
-
audioAlarmActiveOnOverloadImminent (3): Cause the
audio alarm to sound when the load on the MasterSwitch
VM unit exceeds the high load warning threshold, as
defined by the
sPDUMasterConfigVMHighLoadWarningThreshold OID.
Define the threshold that indicates when the power
consumption of the load is approaching an overload
condition. The value is specified as a percentage of a full
load.
Define the threshold that indicates when the power
consumption of the load is approaching a low-consumption
condition. The value is specified as a percentage of a full
load.
Control the behavior of the MasterSwitch VM unit when an
overload condition is imminent and a request has been made
to turn on additional outlets.
- alwaysAllowTurnOn (1): Always allow the outlets to
turn on.
- restrictOnWarning (2): Do not allow outlets to turn on if
the OID value specified for the High Load Warning
Threshold is exceeded.
- restrictOnOverload (3): Do not allow outlets to turn on
if the MasterSwitch VM unit is in an overload condition
Page view 52