Chapter 8:
[atsStatusOutput] Output OIDs
PowerNet MIB Reference Guide
73
{atsOutputPhaseTable}
{atsOutputPhaseEntry}
atsOutputPhaseTableIndex
atsOutputPhaseIndex
atsOutputVoltage
atsOutputCurrent
atsOutputMaxCurrent
atsOutputMinCurrent
atsOutputLoad
atsOutputMaxLoad
atsOutputMinLoad
atsOutputPercentLoad
atsOutputMaxPercentLoad
atsOutputMinPercentLoad
atsOutputPower
atsOutputMaxPower
atsOutputMinPower
atsOutputPercentPower
atsOutputMaxPercentPower
atsOutputMinPercentPower
A tabled set of OIDs providing the following information for each output phase:
Parameters that are unsupported by your model of the Automatic Transfer
Switch return 1.
The output identifier.
Description of each output phase used in this device and one for neutral: phase
1 (1), phase 2 (2), phase 3 (3), and neutral (4).
The output voltage in VAC.
The output current, in 0.1 Amps, drawn by the load on the Automatic Transfer
Switch
The maximum output current in 0.1 Amps recorded since the last time this
value was read or reset by atsStatusResetMaxMinValues
The minimum output current in 0.1 Amps recorded since the last time this value
was read or reset by atsStatusResetMaxMinValues.
The output load in VA.
The maximum output load in VA recorded since the last time this value was
read or reset by atsStatusResetMaxMinValues.
The minimum output load in VA recorded since the last time this value was
read or reset by atsStatusResetMaxMinValues.
The percentage of the Automatic Transfer Switchs load capacity being used on
this output phase at a redundancy of (n + x).
The maximum percentage of the Automatic Transfer Switchs load capacity
being used on this output phase at a redundancy of (n + x) that has been
recorded since the last time this value was read or reset by
atsStatusResetMaxMinValues.
The minimum percentage of the Automatic Transfer Switchs load capacity
being used on this output phase at a redundancy of (n + x) that has been
recorded since the last time this value was read or reset by
atsStatusResetMaxMinValues.
The output power in Watts.
The maximum output power in Watts recorded since the last time this value was
read or reset by atsStatusResetMaxMinValues.
The minimum output power in Watts recorded since the last time this value was
read or reset by atsStatusResetMaxMinValues.
The percentage of the Automatic Transfer Switchs power capacity being used
on this output phase at a redundancy of (n + x).
The maximum percentage of the Automatic Transfer Switchs power capacity
being used on this output phase at a redundancy of (n + x) that has been
recorded since the last time this value was read or reset by
atsStatusResetMaxMinValues.
The minimum percentage of the Automatic Transfer Switchs power capacity
being used on this output phase at a redundancy of (n + x) that has been
recorded since the last time this value was read or reset by
atsStatusResetMaxMinValues.