hsannexbtype Default |
Anfp | AnnexbOrAnfp
This object allows the customer to choose
between support for Annex B, Annex B with
Access Network Frequency Plan (ANFP), or
both.
Type: Modify -- Optional
autoretrain disable |
enable
Enables or disables auto-retrain.
Type: Modify -- Optional
arcrcchk disable | enable
Enables or disables auto-retrain based on
CRC errors.
Type: Modify -- Optional
arfrmrsynchk disable |
enable
Enables or disables auto-retrain based on
framer synchronization.
Type: Modify -- Optional
arsnrmarginchk disable |
enable
Enables or disables auto-retrain based on
whether the S/N margin falls below a preset
threshold.
Type: Modify -- Optional
arcrcthresh <arcrcthresh-
val>
Sets the threshold for the number of frames
with CRC errors for autoretrain.
Type: Modify -- Optional
Valid values: 0 - 0x400
arsnrmarginthresh 1 | 2 |
3 | 4 | 5 | 6
Set the margin threshold for autoretrain.
Type: Modify -- Optional
artime 1 | 2 | 3 | 4 | 5 | 6 |
7 | 8 | 9 | 10
Sets the time over which the autoretrain
parameters must be outside their normal
ranges, so that an auto-retrain occurs.
Type: Modify -- Optional
opstatetrap enable |
disable
Enables/disables trap indicating a change in
op state.
Type: Modify -- Optional
txfrmrdataclkedge
Negative | Positive
This parameter is for Serial ATM applications
only. It is recommended that the default value
be used. For special customer configurations,
transmit data can be sampled upon either
rising or falling edge of the transmit clock.
Type: Modify -- Optional
rxfrmrdataclkedge
Negative | Positive
This parameter is for Serial ATM applications
only. It is recommended that the default value
be used. For special customer configurations,
receive data can be valid upon either rising or
falling edge of the receive clock.
Type: Modify -- Optional
txfrmrpulseclkedge
Negative | Positive
This parameter is for Serial ATM applications
only. It is recommended that the default value
be used. For special customer configurations,
the transmit frame pulse can be active upon
either rising or falling edge.
Type: Modify -- Optional
rxfrmrpulseclkedge
Negative | Positive
This parameter is for Serial ATM applications
only. It is recommended that the default value
be used. For special customer configurations,
the transmit frame pulse can be active upon
either rising or falling edge.
Type: Modify -- Optional
Page view 306
1 2 ... 302 303 304 305 306 307 308 309 310 311 312 ... 602 603

Comments to this Manuals

No comments