Application Note
54
6.3 System Information
This section describes how to get and input the information of the ADSL2/2+ IP
DSLAM.
1. Double Click on “System Information” from the Function List Window.
The System Information window appears as follows:
Input necessary information on those fields.
Table 4-1 Sysinfo field definition
Field Definition
Name Alias name of the ADSL2/2+ IP DSLAM
Location Location of the ADSL2/2+ IP DSLAM
Contact The contact person of the ADSL2/2+ IP DSLAM
Vendor The vendor of the ADSL2/2+ IP DSLAM
Object ID Vendor ID
DST This specifies if the Daylight Savings Time has been
enabled or not.
True:on
False: off
UpTime System up time
HwVersion Hardware version of the ADSL2/2+ IP DSLAM.
CPSwVersion Control plant version
Log Threshold This specifies the severity level of the trap equal to or
lower than that shall be logged. 0 represents log
threshold is diable. 1 is the lowest and represents
critical traps.
Valid values: 0-4
Time Zone Time zone
Valid values: Given below, are the valid values,
followed by their descriptions.
IDLW - International Date Line West
NT - Nome
HST - Hawaii Standard
Page view 61