APC IP DSLAM User's Guide Page 295

  • Download
  • Add to my manuals
  • Print
  • Page
    / 603
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 294
287
threshes <threshes-
val>
This object configures the threshold for the number
of errored seconds (ES) within any given 15-minute
performance data collection interval.
Type: Modify -- Optional
Valid values: 0 - 900
threshses
<threshses-val>
This object configures the threshold for the number
of severely errored seconds (SES) within any given
15-minute performance data collection interval.
Type: Modify -- Optional
Valid values: 0 - 900
threshcrcanom
<threshcrcanom-
val>
This object configures the threshold for the number
of CRC anomalies within any given 15-minute
performance data collection interval.
Type: Modify -- Optional
Valid values: 0 - 0xFFFFFFFF
threshlosws
<threshlosws-val>
This object configures the threshold for the number
of Loss of Sync Word (LOSW) Seconds within any
given 15-minute performance data collection interval.
Type: Modify -- Optional
Valid values: 0 - 900
threshuas
<threshuas-val>
This object configures the threshold for the number
of unavailable seconds (UAS) within any given 15-
minute performance data collection interval.
Type: Modify -- Optional
Valid values: 0 - 900
Example
$ get shdsl endpoint alarmprofile ifname dsl-0
Output
IfName : dsl-0 ThreshLoopAttn : 10
ThreshSNRMrgn : 10 ThreshES : 2
ThreshSES : 10 ThreshCRCAnom : 10
ThreshLOSWS : 10 ThreshUAS : 10
Output field
Field Description
IfName
Name of the end point alarm configuration profile.
ThreshLoopAttn
This object configures the loop attenuation alarm
threshold.The only range supported is 1 to 127.
ThreshSNRMrgn
This object configures the SNR margin alarm
threshold.The only range supported is 0 to 15.
ThreshES
This object configures the threshold for the number
of errored seconds (ES) within any given 15-minute
performance data collection interval.
ThreshSES
This object configures the threshold for the number
of severely errored seconds (SES) within any given
15-minute performance data collection interval.
ThreshCRCAnom
This object configures the threshold for the number
of CRC anomalies within any given 15-minute
performance data collection interval.
ThreshLOSWS
This object configures the threshold for the number
of Loss of Sync Word (LOSW) Seconds within any
given 15-minute performance data collection
Page view 294
1 2 ... 290 291 292 293 294 295 296 297 298 299 300 ... 602 603

Comments to this Manuals

No comments