309
defined in ITU-T G.991.2, for the STU at the
other end of the loop.
RemProviderCode
This object identifies the provider code word, as
defined in ITU-T G.991.2, for the STU at the
other end of the loop.
Loc Detect
This object is used to determine if carrier has
been lost.
Tx Power
This object identifies the local STU transmit
power in tenths of a dBm.
FrmrSync
This object returns information regarding the
framer synchronization status.
RemTomData
This object provides vendor-provided data, as
defined in ITU-T G.991.2, for the STU at the
other end of the loop.
Drift Alarm
This object identifies if the receive clock is in or
out of range.
RecvGain
This object provides the total receiver gain in
dB.
Bert Error
This object provides the count of bit errors since
the last time the object was read, as well as the
type of synchronization.
RemFwVer
This object provides the transceiver firmware
release number of the STU at the other end of
the loop.
Utopia CD
This object indicates whether cell delineation
has been found.
UtopiaRxCellCnt
This object indicates the number of UTOPIA
cells received since the last time the object has
been called. The maximum value is 0xFFFF.
UtopiaCellDropCnt
This object indicates the number of UTOPIA
cells dropped since the last time the object has
been called. The maximum value is 0xFF.
UtopiaRxHECErrCnt
This object indicates the number of UTOPIA
cells with HEC errors since the last time the
object has been called. The maximum value is
0xFF.
UtopiaTxCellCnt
This object indicates the number of UTOPIA
cells transmitted since the last time the object
has been called. The maximum value is 0xFFFF.
RemNsfCusId
This object returns the customer identification
that was sent by the STU at the other end of the
loop.
RemTxPower
This object provides the transmit power of the
STU at the other end of the loop.
RemPowerBackoff
This object indicates whether power backoff is
enabled or disabled at the STU at the other end
of the loop.
AutoRetrainCnt
This object indicates the number of automatic
retrains. This counter is only reset when a
startup is initiated.
Eoc State
This object provides status information about
the eoc stage.
Ntr Fault
This object identifies the Network Timing
Recovery Fault.
ParamTestResult
Indicates the Result of the Parametric Test
conducted on the Xcvr.