unsolicrprtinterval
<unsolicrprtinterval-
val>
This parameter specifies the interval between
unsolicited membership reports of a group sent for
robustness no of times.This field is applicable only
when proxy reporting is enabled.
Type: Modify -- Optional
Valid values: 1 - 0xff
Example
$ get igmpsnoop cfg info
Output
Query Interval : 12 Query Response
Interval : 10
StartUp Query Interval : 10
UnSolicRprtInterval : 10
Anxious Timer : 125 V1 Host
Timer : 130
Last Member Query Interval : 125 Robustness
Variable : 2
Igmp Snoop Status : Enable
Version Mask : v3
Report Suppression Status : Enable Proxy Report
Status : Enable
StartUp QryCount : 2 Last Member
QryCount : 100
Output field
Field Description
Query Interval
This parameter is used to calculate the entry age
out timer, when no reports or queries are
received on the entry. When the value of this
parameter multiplied by 10, it should be greater
than the Query Interval configured at the router.
The time for which an entry created at
Igmpsnoop module exists, if no messages are
received for it is approximately
(((QueryInterval*10)*Robustness) + Query
Response Time received in Last Query)
Query Response
Interval
This parameter is used to derive Max Response
Code to be filled in General query that will be
initiated from Columbia
StartUp Query Interval
This parameter specifies the interval between
General Queries sent on receiving Port Up
topology change trigger.
UnSolicRprtInterval
This parameter specifies the interval between
unsolicited membership reports of a group sent
for robustness no of times.This field is applicable
only when proxy reporting is enabled.
Anxious Timer
This parameter specifies the maximum time (in
seconds) before which the IgmpSnoop module
will forward all IGMP membership reports
received. It is started once, whenever the first
membership report is received for a group, to
ensure that reports are forwarded for a
sufficiently long time, to take care of any lost
reports. The unit is seconds.
V1 Host Timer
This parameter specifies the maximum time (in
seconds), for which the IgmpSnooping module
can assume that there are Version 1 group
members present, for the group for which this
timer is running. The unit of this parameter is
seconds.