APC IP DSLAM User's Guide Page 538

  • Download
  • Add to my manuals
  • Print
  • Page
    / 603
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 537
530
Name Description:
Numentries
<numentries-val>
This specifies last numentries idle time records
to be displayed
Type: Optional
Valid values : 1 to 6
Default : 10
Mode
Super-User, User
Example
$ get rmon idletime numentries 1
Output
$get rmon idletime numentries 1
Start Time End Time Total
Idle Util %
Time
Time
--------------------------------------------------------------
-------------
Thu Jan 1 12:34:51 1970 Thu Jan 1 12:35:00 1970 10s 7s 30
Output Fields
FIELD Description
Start Time
This specifies the starting time of the period for
which the idle time was recorded
End Time
This specifies the end time of the period for
which the idle time was recorded
Total Time
This specifies the total time (in seconds) elapsed
in this period.
Idle Time
This specifies the time (in seconds) for which the
system was idle during this period.
Util %
This specifies the Utilization (in percentage) of
the system during this period
8.25.6 System manuf info Commands
8.25.6.1 Get system manuf info
Description: This command is used to display manufacturing text
information in the system.
Command Syntax: get system manuf info
Example $ get system manuf info
Output
CpeUtopiaMode : Tx 16 Bit Rx 8 Bit
NetUtopiaMode : Tx 16 Bit Rx 8 Bit
CpeUtopiaMaster : True NetUtopiaMaster :
False
MaxEthMacPhy : 2 ColumbiaIdSel :
18
CpeUtopiaFreq : 40 MHz
Eth Speed : 100 Mbps
Page view 537
1 2 ... 533 534 535 536 537 538 539 540 541 542 543 ... 602 603

Comments to this Manuals